Gauge: 29
Weight: 1.98 lb. /LF
Steel Yield Stress: 80,000 psi
Galvanized Steel Gauge, AZ-50
Paint System: Baked-on Silicone Modified Polyester Gauging System: Miramac, Inc. follows the national A.I.S.I. (American Iron and Steel Institute) specifications manual for tolerances in galvanized sheet metal.
All gauges conform to ASTM A446 Grade E (80,000 min. yield) unless otherwise designated at time of order
| Live Load |
Uplift Load |
|||||||
| (Strength) | (Internal Pressure) | |||||||
| SPAN | 2’ | 3’ | 4’ | 5’ | 2’ | 3’ | 4’ | 5’ |
| (in feet) | ||||||||
| 29 Gauge |
113 | 45 | 19 | 10 | 113 | 59 | 33 | 21 |
| (Simple Span) | ||||||||
| 29 Gauge |
119 | 69 | 36 | 18 | 119 | 74 | 42 | 27 |
| (Continuous Span) | ||||||||
1 ½” Bearing Length
Load Span Tables Based on Working Stress. Flexural Design analysis according to AISI “Specification for the Design of Light Gauge Cold-Formed Steel Structural Members” May 1981. Continuous Span Loading applies to sheets continuous over three or more spans
Weight of sheet has not been allowed for when calculating live load and Uplift.
Deflection (L/180) limiting live load based on deflection of span. Metal thickness based on minimum ASTM specifications for allowable load calculations. Loads may be increased by 1/3 for wind loads
Note: The load tables have been compiled for the design of steel roofing and siding used in conjunction with either wood or steel framed structures. Miramac, Inc. assumes no responsibility, either expressed or implied, for its use.
| Wind Speed | Live Loads (lbs. per Square Foot) |
| 70 mph | 12.6 |
| 80 mph | 16.4 |
| 90 mph | 20.8 |
| 100 mph | 25.6 |
| 110 mph | 31.0 |
| 120 mph | 36.9 |
| 130 mph | 43.3 |
Areas of discontinuity are subject to higher spikes in wind pressure, therefore a different coefficient in wind pressure will need to be considered and multiplied by a factor of 1.5Data from: 1994 UBC Table
Roof Application: Fasteners to be applied along side every rib and attached to each purlin. Please note that it is the responsibility of the builder to insure that purlins are adequately spaced to meet specific engineering requirements.
Miramac Inc. is nether partially nor solely responsible for improper installation or defects as a result of installation.
Note: If panels are to be cut, or pre-drilled, be certain to wipe free any metal chips that have accumulated on the panel.
Wall Screw Application: Fasteners to be applied along side every rib and attached to each girt. Please note that it is the responsibility of the builder to insure girts are adequately spaced to meet specific engineering requirements.
Coming Soon!
| SNAP LOCK 12" COVERAGE | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MATERIAL SPECIFICATIONS | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Gauge: 26,24
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| APPLICATION DETAILS | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Construction No. 529 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| LOAD TABLES | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||